Our automated cell counters are equipped with high quality optics and sophisticated software to bring you cell concentration and viability data with incredible speed, accuracy, and reliability. 4. no. The Countess II Fl also has a 2.5x objective, and a 5-megapixel camera to capture images, and powerful software for rapid assessment. You can create custom, cell-specific cell counting protocols or simply use the default counting protocol suitable for most cell lines. Wear appropriate protective eyewear, clothing, and gloves. Each chamber slide contains two enclosed chambers to hold the sample to allow you to measure two different samples or perform replicates of the same sample. Instrument exterior components . C-Slide – Countess Cell counting chamber slides. Countess ™ Cell Counting Chamber Slides (50 slides/box) 1 box Countess ™ 3 Disposable Slide Holder 1 each Countess ™ 3 Reusable Slide Holder 1 each Countess ™ 3 USB Drive 1 each Countess ™ 3 Automated Cell Counter Quick Reference Card 1 each. Each slide contains two cell counting chambers (75 mm × 25 mm × 1.8 mm; chamber depth = 100 µm). 3 FL Automated Cell Counter accepts both the disposable Countess ™ Cell Counting Chamber Slides and the glass Countess ™ 3 FL Reusable Slides via interchangeable, slide-specific carriers. Includes Removable Slide Holder, current validation, and a 30 Day Warranty. Countess™ Cell Counting Chamber Slidesor in glass Countess ™ II FL Reusable Slides (page 15). What size of cells are the Invitrogen ™ Countess II Automated Cell Counter and Invitrogen ™ Countess II FL Automated Cell Counter able to count… Thermo Countess II FL Cell Counter In Box is available from The Lab World Group. Read independent reviews on Invitrogen™ Countess™ 3 FL Automated Cell Counter from Thermo Fisher Scientific on SelectScience However, the standard practice of manual cell counting is usually to count ~100 cells, or a specific volume such as 0.4 µl, regardless of the concentration of cells. " Cell counter Countess II stands out for its ease of use. Substitutes Countess® Order Number C10314: CEVS-2500: 2.731,00 € 5.000 Cell Counting Slides ( 10.000 counts ) For the use with the Countess® Cell Counter. The cell counting algorithm then automatically identifies the cell population of interest without requiring user input. NanoEnTek is an original developer and manufacturer of Countess and Countess Slide. Cells Counted with the TC20™ Automated Cell Counter. The Countess II Automated Cell Counter uses trypan blue staining combined with an auto-focus mechanism and sophisticated image analysis algorithm to obtain accurate cell and viability counts. This counter comes with an EVOS Texas Red Light Cube for use with Ethidium Homodimer-1. Our group is looking into getting a Countess II FL Cell Counter from Life Technologies (link). The Countess II FL Automated Cell Counter uses trypan blue staining combined with an auto-focus mechanism and sophisticated image analysis algorithm to obtain accurate cell and viability counts. For use at room temperature under normal laboratory conditions. Drawbacks are the price and that it needs its own slides for counting that cost a lot. " no. It’s straightforward. This cell counter is the only device to bring the accuracy and consistency of Coulter impedance counting right to the culture hood. Touch-screen display: The 7-inch capacitive touch-screen display is the main user interface of the Countess ™ II Automated Cell Counter. Countess ™ cell counting chamber slides that contain two enclosed chambers to hold the sample to allow you to measure two different samples or perform replicates of the same sample. For more information, see Chapter 4, “Slide preparation and operation”. Review date: 20 Aug 2015 | Invitrogen™ Countess II Automated Cell Counter Read the Safety Data Sheets (SDSs) and follow the handling instructions. For more information, please visit us at It’s simple. Scepter 2.0 Handheld Automated Cell Counter Rapid cell counts in a handheld easy to use format, includes pkg of 40 μm Scepter Cell Counter Sensors; find Millipore-PHCC20040 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich. The measurement range extends from 1 x 10e4 to 1 x 10e7 cells/mL (the optimal range is 1 x 10e5 to 4 x 10e6 cells/mL), which is broader than that of a hemocytometer. Press count and the LUNA-II™ does the rest – bringing your cells into the sharpest focus, adjusting light levels, capturing a high-resolution image, and analyzing the image to produce accurate cell count and viability data. MAN0014293). Counting Yeast Cells for Brewing and Wine Industries Can Be Facilitated by the Scepter 2.0 Handheld Automated Cell Counter: Precise and Accurate Bead Counting Using the Scepter 2.0 Handheld Automated Cell Counter: Predicting Cell Death by Rapidly Assessing Size Changes with the Scepter Cell Counter C-Slide is the same as Countess Slide. MAN0010826 Rev. cell counting listed below and ranked in order of importance, one can minimize variability and maximize cell counting confidence. Substitutes Countess® Order Number C10315: CEVS-5000: 5.175,00 € Test Beads. Read independent reviews on Invitrogen™ Countess™ 3 Automated Cell Counter from Thermo Fisher Scientific on SelectScience